Products
Model: CIT-5K/6K/8K/10K/12K-H
Three-Phase Hybrid Inverter
System Technology
Flexible Design & Use
● DC 16A current input, compatible with high power PV module;
● Supports application in retrofit scenario;
● UPS Switching time <10ms;
Energy Independence
● Fast charging / discharging to meet the demand of higher consumption;
● 110% continuous AC output overloading;
● 130% max. AC output overloading@85s;
Convenient Installation & Operation
● Unique push-in connectors for time-saving installation;
● Touch free commissioning with smartphone;
● Compact size and elegant appearance;
Smart Management
● Remote firmware update and customizable settings;
● Free online monitoring to enhance energy manage ment for end user, installer and retailer;
● Programmable supply priority for PV, Battery or Grid;
Product Parameters
MODEL |
CIT-5K-H |
CIT-6K-H |
CIT-8K-H |
CIT-10K-H |
CIT-12K-H |
PV (DC) |
|||||
Recommended Max. PV Input Power |
7500 Wp |
9000 Wp |
12000 Wp |
15000 Wp |
18000 Wp |
Max. Input Voltage |
1000 V |
||||
Start-up Voltage |
135 V |
||||
Rated Input Voltage |
600 V |
||||
MPPT Input Voltage Range |
135-900 V |
||||
MPPT Max. Input Current |
16 A / 16 A |
16 A / 32 A |
|||
MPPT Short-circuit Current |
20 A / 20 A |
20 A / 40 A |
|||
No. of MPPT |
2 |
||||
No. of Strings per MPPT |
1 / 1 |
1 / 2 |
|||
Grid (AC) |
|||||
Max. Input Apparent Power |
10000 VA |
12000 VA |
16000 VA |
20000 VA |
24000 VA |
Rated Output Power |
5000 W |
6000 W |
8000 W |
10000 W |
12000 W |
Max. Output Apparent Power |
5500 VA |
6600 VA |
8800 VA |
11000 VA |
13200 VA |
Rated AC Voltage |
3L/N/PE , 220/380 V, 230/400 V, 240/415 V |
||||
Input/Output Voltage Range |
180-300 V / 200-253 V |
||||
Rated Output Voltage Frequency |
50 / 60 Hz |
||||
Input/Output Voltage Frequency Range |
(45-55) ; (55-65) Hz |
||||
Rated Output Current |
7.2 A |
8.7 A |
11.6 A |
14.5 A |
17.4 A |
Max. Input/Output Current |
15.2 A / 9.8 A |
18.2 A / 11.8 A |
24.2 A / 15.8 A |
30.3 A / 19.7 A |
36.4 A / 23.6 A |
Power Factor (Rated) |
>0.99 |
||||
Adjustable Power Factor Range |
0.8 leading ... 0.8 lagging |
||||
Total Harmonic Distortion |
<3% (Rated Power) |
||||
Grid Connection Mode |
3L/N/PE |
||||
AC Load Output (Off-grid) |
|||||
Rated Output Power |
5000 W |
6000 W |
8000 W |
10000 W |
12000 W |
Max. Output Apparent Power |
5500 VA |
6600 VA |
8800 VA |
11000 VA |
13200 VA |
Rated Output Voltage |
3L/N/PE , 220/380 V, 230/400 V, 240/415 V |
||||
Output Voltage Range |
200-240 V |
||||
Rated Output Frequency |
50/60 Hz |
||||
Rated Output Current |
7.2 A |
8.7 A |
11.6 A |
14.5 A |
17.4 A |
Max. Output Current |
9.8 A |
11.8 A |
15.8 A |
19.7 A |
23.6 A |
Total Harmonic Distortion |
<3% (R Load) |
||||
On-grid/Off-grid Switching Time |
<10 ms |
||||
Battery (DC) |
|||||
Rated Output Power |
5000 W |
6000 W |
8000 W |
10000 W |
12000 W |
Max.Charge/Discharge Power |
12500 W / 5500 W |
12500 W / 6600 W |
12500 W / 8800 W |
12500 W / 11000 W |
12500 W / 13200 W |
Battery Voltage Range |
135-800 V |
||||
Max. Charge/Discharge Current |
25 A / 25 A |
||||
Communication Port |
CAN / RS485 |
||||
Efficiency |
|||||
Max. Efficiency |
97.6% |
||||
Max. MPPT Efficiency |
99.9% |
||||
Max. European Efficiency |
97.0% |
||||
Protection |
|||||
Integrated Protection |
Anti-flow Protection, DC Reverse Protection, DC Circuit Breaker, Insulation Resistor Detection, Leakage Current Monitoring,Output Shorted Protection, Output Over Current Protection, Grid Monitoring, Anti- islanding Protection,Residual Current Monitoring, Reverse Polarity Protection, Off-grid Overload Protection. |
||||
Surge Protection |
DC Type II, AC Type II |
||||
Display and Communication |
|||||
Display |
LED+APP |
||||
Communication |
Yes: RS485 / USB , Optional: 4G / WiFi |
||||
General Data |
|||||
Dimensions (W*H*D) |
516 x 442 x 222 mm |
||||
Weight |
24 kg |
||||
Operating Temperature Range |
-30~60℃ |
||||
Noise |
<35 dB |
||||
Cooling |
Smart Cooling |
||||
Installation Style |
Wall-mounted |
||||
Protection Rating |
IP66 |
||||
Warranty |
10 Years |
||||
Standards Compliance |
|||||
Grid Connection |
G98/G99, EN 50549/50438, CEI 0-21, AS 4777.2, VDE 4105/0126, RD1699/661/413/244/2019, UNE 206006/206007, NTS Type A, UNE 217002/217001 |
||||
Safety Regulation |
EN/IEC 62109-1/2 |
||||
Others |
EN/IEC 61000-6-1/2/3/4 |
Product specifications are subject to change without further notice.
Contact Us
Enterprise Phone
+92 3119889977 Sales Manager
+92 3495698826 Sales Manager
Enterprise E-mail
©2024 Ningbo HWOO Energy Storage Technology Co., Ltd.
COOKIES
Our website uses cookies and similar technologies to personalize the advertising shown to you and to help you get the best experience on our website. For more information, see our Privacy & Cookie Policy
COOKIES
Our website uses cookies and similar technologies to personalize the advertising shown to you and to help you get the best experience on our website. For more information, see our Privacy & Cookie Policy
These cookies are necessary for basic functions such as payment. Standard cookies cannot be turned off and do not store any of your information.
These cookies collect information, such as how many people are using our site or which pages are popular, to help us improve the customer experience. Turning these cookies off will mean we can't collect information to improve your experience.
These cookies enable the website to provide enhanced functionality and personalization. They may be set by us or by third-party providers whose services we have added to our pages. If you do not allow these cookies, some or all of these services may not function properly.
These cookies help us understand what you are interested in so that we can show you relevant advertising on other websites. Turning these cookies off will mean we are unable to show you any personalized advertising.